IEC 61334-6 PDF

Buy IEC Ed. Distribution automation using distribution line carrier systems Part 6: A-XDR encoding rule from SAI Global. IEC (), Distribution automation using distribution line carrier systems. Part 6: A-XDR encoding rule: Defines a set of encoding rules that may be. Purchase your copy of BS EN , IEC as a PDF download or hard copy directly from the official BSI Shop. All BSI.

Author: Visar Mekus
Country: Brazil
Language: English (Spanish)
Genre: Sex
Published (Last): 8 September 2013
Pages: 225
PDF File Size: 1.94 Mb
ePub File Size: 4.14 Mb
ISBN: 361-2-85279-641-2
Downloads: 22988
Price: Free* [*Free Regsitration Required]
Uploader: Fenrigami

The physical layer synchronizes a small packet of tones to the zero-crossing of the power line’s voltage. IECknown as Distribution automation using distribution line carrier systemsis a standard for low-speed reliable power line iex by electricity meterswater meters and SCADA. Please download Chrome or Firefox or view our browser tips. Click to learn more. The standard’s low speed is caused by the limited number of bits per power line cycle.

The system should be able to adjust the receiving method on each byte packet. The silence and the preamble allow 6334-6 receiver’s signal processing to measure the channel’s noise ratios.

IEC – Wikipedia

Electric power distribution, Electric power transmission, Electric power distribution lines, Data transmission, Electric power transmission networks, Electric power networks, Automatic control systems, Control systems, Coding data conversionCodes, Data handling, Data syntax, Data transfer. You may experience issues viewing this site in Internet Explorer 9, 10 or eic The high reliability comes from its reliable timing system i.

Each byte is collected into byte packets. The most significant bits are sent first, unlike a conventional serial port. The higher link-layer strongly resembles HDLCexcept with a novel feature that allows selected stations to retransmit messages.

  ELECAM CAMEROUN PDF

A-XDR encoding rule Status: The tones are chosen by utilities, not specified in the standard. Wide area networks Networking standards. The frequencies are placed far enough apart that frequency-selective fading and narrow-band interference only blocks one of the frequencies, so the receiver can still recover all the data from the other frequency.

Learn more about the cookies we use and how to change your settings. In multiphase power lines, 613346- separate signal might be sent on each phase to speed up the transmission. The standard permits each zero-crossing to convey 1, 2, 4 or 8 bits, with increased sensitivity to timing as the number of bits 63134-6.

The first four 6334-6 of each packet are a preamble to measure the channel’s current condition.

Accept and continue Learn 63134-6 about the cookies we use and how to change your settings. It is actually a series of standards describing the researched physical environment of power lines, a well-adapted physical layer, a workable low-power media access layer, and a management interface.

You may find similar items within these categories by selecting from the choices below:. Verteilungsautomatisierung mit Hilfe von Traegersystemen auf Verteilungsleitungen. Depending on the signal to noise ratios, the bits can be recovered from the difference between the power of the mark and space tones, the power of the mark tones only, or the space tones only.

The physical layer is adaptive. Your basket is empty. By using this site, you agree to the Terms of Use and Privacy Policy. 6334-6 data from zero crossings should be collected into 8-bit bytes. Views Read Edit Ied history. Search all products by. From Wikipedia, the free encyclopedia. One tone is chosen for mark i.

  DESCARGAR COMPORTAMIENTO HUMANO EN EL TRABAJO NEWSTROM PDF

Related standards use the physical layer e. List of International Electrotechnical Commission standards.

BS EN 61334-6:2001, IEC 61334-6:2000

isc S-FSK spread frequency-shift keying is a modulation scheme that combines some of the advantages of classical spread-spectrum modulation immunity against narrow-band interference with some of the advantages of classical frequency-shift keying FSK is low complexity. Automatisation de la distribution a l’aide de systemes de communication a courants porteurs. Take the smart route to manage medical device compliance. Retrieved from ” https: For example, it lets a central controller read a unit’s signal to noise ratios, and set the bit that enables a station to retransmit weak stations.

GSO IEC – Standards Store – GCC Standardization Organization

This website is best viewed with browser version of up to Microsoft Internet Explorer 8 or Firefox 3. This page was last edited on 30 Marchat We use cookies to make our website easier to use and to better understand your needs.

Find Similar Items This product falls into the following categories. The bytes from the low-layer packets are 61334-6 into bytes for the higher layers. This is followed by 38 bytes of data, and 3 byte-times of silence.

The faster, easier way to work with standards.